Last modified by writer on 2023/09/06 20:00

From version 3.1
edited by writer
on 2023/02/09 16:36
Change comment: There is no comment for this version
To version 5.1
edited by writer
on 2023/09/06 20:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,13 +6,10 @@
6 6  
7 7  The selection and adjustment of the operating mode is carried out on the tab “Configuration” → “Settings” → “Oxy-Fuel”.
8 8  
9 -[[image:2019-09-06 11_44_28-Settings.png||alt="Window ~"Settings~" of the oxy-fuel module" data-xwiki-image-style-alignment="center" height="558" width="900"]]
9 +[[Window "Settings" of the oxy-fuel module>>image:2019-09-06 11_44_28-Settings.png||alt="Window ~"Settings~" of the oxy-fuel module" data-xwiki-image-style-alignment="center" height="558" width="900"]]
10 10  
11 -(% class="imagetext" style="color: gray; text-align: center;" %)
12 -Window "Settings" of the oxy-fuel module
11 +==== External Z Control ====
13 13  
14 -===== (% style="color:#007a7a" %)**External Z Control**(%%) =====
15 -
16 16  This mode involves the use of a stand-alone flame torch height controller (CHC-400 and others). The Z axis (including the motor) is controlled in this mode by the autonomous axis controller.
17 17  
18 18  To ensure interaction with an external autonomous axis, the following set of signals is used in PUMOTIX:
... ... @@ -28,7 +28,7 @@
28 28  * **LimitHight Signal Input**
29 29  The OxyExternalZLimitHight signal is used to interact with the sensor of the extreme upper position of the torch of the autonomous Z axis (if such a sensor is present). When using a sensor, the PUMOTIX control system raises the Z axis until a signal is received from the sensor. Lifting is carried out for safe movement of the torch between cutting contours, as well as when you click on the “Stop” button with the active option “Allow Safe_Z moves”. Signal settings are on the “[[IO>>doc:Руководство пользователя.Настройка ПО.Настройка сигналов.WebHome]]” tab.
30 30  
31 -===== (% style="color:#007a7a" %)**Up/Down Control**(%%) =====
28 +==== Up/Down Control ====
32 32  
33 33  The mode is designed to control the torch torch height using the UP/DOWN protocol. Used with an external oxy-fuel cutting height controller that generates UP/DOWN control signals. In the absence of an external height controller, a circuit with two buttons connected to the PLCM controller inputs can be used.
34 34  
... ... @@ -39,13 +39,10 @@
39 39  * **Entry down**
40 40  The input responsible for correcting the cutter down. Connects to the DOWN output of an external torch torch height controller. If there is no controller, a manual control button can be connected to the input according to the operating instructions to the PLCM controller.
41 41  
42 -===== (% style="color:#007a7a" %)**Manual control**(%%) =====
39 +==== Manual control ====
43 43  
44 44  Used in the absence of both standalone Z axis controllers and torch torch height controllers using the UP/DOWN protocol. Correction of the torch height above the metal in this mode is carried out manually using the "Up" and "Down" buttons.
45 45  
46 -[[image:image2019-9-10_14-6-4.png||alt="Buttons for height correction in manual mode of the Z axis" data-xwiki-image-style-alignment="center"]]
43 +[[Buttons for height correction in manual mode of the Z axis>>image:image2019-9-10_14-6-4.png||alt="Buttons for height correction in manual mode of the Z axis" data-xwiki-image-style-alignment="center"]]
47 47  
48 -(% class="imagetext" style="color: gray; text-align: center;" %)
49 -Buttons for height correction in manual mode of the Z axis
50 -
51 51  In manual control mode, no additional input and output signals are required. When you press the Up and Down buttons, the Z axis moves with the specified height adjustment speed.