Changes for page Настройка приводного рольганга
Last modified by writer on 2024/09/25 14:21
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,12 +5,8 @@ 1 -{{info}} 2 -**This page didn't translate yet. You can see the original page.** 3 -{{/info}} 4 - 5 5 The PUMOTIX feature allows you to configure one or more motors to control the rollgang. 6 6 7 7 Make sure that you have access to a license to control the rollgang before setting up. You can check the availability of a license for a feature in the menu "Configuration" → "License Manager". Expand the "General Features" node in the PUMOTIX features tree. You can use the trial period if the "Controlled rollgang support" feature is not activated. 8 8 9 -[[Activation of the trial period of the "Controlled rollgang support" feature>>image: image2020-8-26_9-2-47.png||data-xwiki-image-style-alignment="center" height="500" width="694"]]5 +[[Activation of the trial period of the "Controlled rollgang support" feature>>image:Controlled rollgang support feature trial.png||alt="Activation of the trial period of the ~"Controlled rollgang support~" feature" data-xwiki-image-style-alignment="center" height="500" width="699"]] 10 10 11 11 As an example, consider the setup of a pipe cutting machine with a rollgang, working in tandem with a rotary axis B. 12 12 ... ... @@ -25,7 +25,7 @@ 25 25 26 26 For the convenience of further configuration, we will rename the rotary axis motors to “Chuck” and “Rollgang”. 27 27 28 -[[Motors Settings>>image: image2020-8-26_7-52-11.png||data-xwiki-image-style-alignment="center" height="548" width="1000"]]24 +[[Motors Settings>>image:Rollgang and Chuck motors.png||alt="Motors Settings" data-xwiki-image-style-alignment="center" height="545" width="1000"]] 29 29 30 30 You need to go to the “Axes” settings tab after setting up the motors. Select the rotary axis from the drop-down list at the top of the window. In this example we use the B axis. 31 31 ... ... @@ -56,69 +56,72 @@ 56 56 The larger the diameter of the pipe, the greater the rotation speed of the rollgang rollers and vice versa. 57 57 {{/info}} 58 58 59 - Длятого,чтобысистемамоглаавтоматическирассчитатьпоправочныйкоэффициентдлясвязидиаметратрубысоскоростьювращенияроликов,необходимовнестивнастройкисистемыследующиеданные:55 +In order for the system to automatically calculate a correction factor for relating the pipe diameter to the roller rotation speed, the following data must be entered into the system settings: 60 60 61 -1. Диаметрприводногороликарольганга(вммилидюймах).62 -1. КоличествоимпульсовSTEPдляповоротароликана1градус.57 +1. Diameter of the rollgang roller (in mm or inches). 58 +1. Count of STEP pulses to rotate the roller by 1 degree. 63 63 64 -{{success title="** КоличествосигналовSTEPдляролика**"}}65 - Параметр"STEPдляролика"долженбытьрассчитантакимобразом,чтобыприподачекомандыG0 B360роликирольгангаделалировноодиноборот.60 +{{success title="**Count of STEP signals for roller**"}} 61 +The "SPU for Rolle" parameter must be calculated in such a way that when the G0 B360 command is issued, the rollgang rollers make exactly one revolution. 66 66 {{/success}} 67 67 68 -[[ Настройкаосей>>image:image2020-8-26_8-3-37.png||data-xwiki-image-style-alignment="center" height="548" width="1000"]]64 +[[Axes Settings>>image:Rollgang Axis Settings.png||alt="Axes Settings" data-xwiki-image-style-alignment="center" height="545" width="1000"]] 69 69 70 - Введитенедостающиезначениявнастройкиприводногорольгангаинажмитекнопку"Применить"вправомнижнемуглуокнанастроек.66 +Enter the missing values in the rollgang settings and click the "Apply" button in the lower right corner of the settings window. 71 71 72 -[[ Расширенныенастройкиприводногорольганга>>image:image2020-8-26_8-31-29.png||data-xwiki-image-style-alignment="center" height="300" width="411"]]68 +[[Advanced settings for the rollgang>>image:Motor Additional Features.png||alt="Advanced settings for the rollgang" data-xwiki-image-style-alignment="center" height="350" width="336"]] 73 73 74 - Обратитевнимание,чтоавтоматическиактивироваласьопция"ЗадатьзначениеSTEPдлядвигателя".ПолезначенияSTEPсталодоступновданномслучаетолькодлячтения.Иконкасжелтымтреугольникомпредупреждаетнасотом,чтозначениеколичестваимпульсовSTEPдлядвигателяприводногорольгангабудетавтоматическирассчитыватьсяисходяиззаданныхпараметроврольгангаидиаметратрубы.Кзаданиюдиаметратрубымыперейдемпозже.70 +Please note that the option "Set SPU for Motor" is automatically activated. The STEP value field has become read-only in this case. The yellow triangle icon warns us that the value of the count of STEP pulses for the rollgang motor will be automatically calculated based on the specified parameters of the rollgang and pipe diameter. We will move on to setting the pipe diameter later. 75 75 76 - Теперьэтотдвигательопределендляуправлениярольгангом,очемвовкладке"Двигатели"свидетельствуетпоявившаясяиконка.72 +Now this motor is defined to control the roller table, as evidenced by the icon that appears in the “Motors” tab. 77 77 78 -[[ Отображениедвигателярольганга>>image:image2020-8-26_8-37-28.png||data-xwiki-image-style-alignment="center" height="401" width="300"]]74 +[[Rollgang motor display>>image:Rollgang Icon in Motors tab.png||alt="Rollgang motor display" data-xwiki-image-style-alignment="center" height="350" width="309"]] 79 79 80 - Наданномэтапенастройкидвигателейиосейможносчитатьзавершенными.76 +At this stage, the settings of the motors and axes can be completed. 81 81 82 - Длятестовогозапускаповоротнойосисприводнымрольгангомнеобходимоопределитьдиаметртрубы,котораябудетиспользоватьсядляобработки.78 +It is necessary to determine the diameter of the pipe that will be used for processing to test run a rotary axis with a driven roller conveyor. 83 83 84 - Диаметртрубывмодуляхплазменной и газокислородной резкиPUMOTIXможнозадатьдвумяспособами:80 +The pipe diameter in PUMOTIX plasma and oxy-fuel cutting modules can be set in two ways: 85 85 86 -1. ИзграфическогоинтерфейсаPUMOTIX.Полевводапараметранаходитсянавкладке**"Параметрыпроцесса"** → **"Диаметртрубы"**.87 -1. СпомощьюспециальногоM-кодаспараметром.Например, (% style="color:#8d69b2" %)**M94 P400**(%%) (где400-диаметртрубы).82 +1. From the PUMOTIX GUI. The parameter input field is located on the "Process parameters" From the PUMOTIX GUI. The parameter input field is located on the **"Process parameters"** tab → **"Pipe diameter"**. 83 +1. Using a special M-code with a parameter. For example, (% style="color:#8d69b2" %)**M94 P400**(%%) (where 400 is the pipe diameter). 88 88 89 -[[image:ima ge2020-8-26_9-6-54.png||data-xwiki-image-style-alignment="center" height="343" width="1000"]]85 +[[image:Pipe Diameter in Process Parameters tab.png||data-xwiki-image-style-alignment="center" height="340" width="1000"]] 90 90 91 -{{warning title="** АвтоматическийрасчетколичестваимпульсовSTEPдлядвигателярольганга**"}}92 - Приизменениизначенияпараметра"Диаметртрубы"выполняетсяавтоматическийпересчетпараметраSTEPтолькодлядвигателя,приводящеговдвижениерольганг.ЗначениепараметраSTEPдлядвигателяповоротнойоси,работающейвпаресрольгангом,приэтомостаетсянеизменным.Такоймеханизмпозволяетвсегдавращатьтрубусодинаковойскоростьюнезависимоотеедиаметра.Скоростьвращениероликоврольгангаприэтомбудетнеявноподстраиватьсяисходяизвведенногодиаметратрубы.87 +{{warning title="**Automatic calculation of the count of STEP pulses for the rollgang motor**"}} 88 +When changing the value of the Pipe Diameter parameter, the SPU parameter is automatically recalculated only for the rollgang motor. The value of the SPU for the motor of the rotary axis operating in tandem with the rollgang remains unchanged. This mechanism allows the pipe to always rotate at the same speed, regardless of its diameter. The rotation speed of the roller table rollers will be adjusted based on the entered pipe diameter. 93 93 {{/warning}} 94 94 95 - ДляподготовкиУПвSheetCam THGрекомендуетсяиспользоватьспециализированныйпостпроцессор:91 +To prepare NC program in SheetCam THG, it is recommended to use a specialized post-processor: 96 96 97 97 (% style="text-align: center;" %) 98 -**[[ Скачатьпостпроцессор>>attach:Pumotix rotary THC.scpost||target="_blank"]]**94 +**[[Download postprocessor>>attach:Pumotix rotary THC.scpost||target="_blank"]]** 99 99 100 - ЧтобывыбратьданныйпостпроцессорвSheetCam,перейдитевменю**Настройки**Установкистанка** → **Postprocessor** → **Import post**иукажитепутькфайлу.96 +To select this postprocessor in SheetCam, go to **Settings **→ **Machine Settings** → **Postprocessor** → **Import post** and specify the path to the file. 101 101 102 - ДлявыгрузкиУПсиспользованиемданногопостпроцессоранеобходимозадатьдиаметртрубы.Дляэтоговспискеоперацийнажмитекнопку**Установкапостпеременной**,извыпадающегоспискаvariable nameвыберитепеременную**diameter**иукажитезначениевнешнегодиаметратрубы.98 +To unload a NC using this postprocessor, you must specify the pipe diameter. To do this, in the list of operations, click the **Set post variable **button, from the variable name drop-down list, select the **diameter** variable and specify the value of the outer diameter of the pipe. 103 103 104 -[[image:rollgang_1.png ]][[image:rollgang_2.png]]100 +[[image:rollgang_1.png||data-xwiki-image-style-alignment="center"]] 105 105 106 -{{warning title="**Порядок следования переменных и операций**"}} 107 -Убедитесь, что в списке операций команда установки переменной находится выше операции плазменной резки. 102 + 103 +[[image:rollgang_2.png||data-xwiki-image-style-alignment="center"]] 104 + 105 +{{warning title="**Order of variables and operations**"}} 106 +Make sure that the Set Variable command is above the Plasma Cutting operation in the list of operations. 108 108 {{/warning}} 109 109 110 - В сформированную УП постпроцессором будет добавлена команда(% style="color:#8d69b2" %)**M94 P400**(%%),сообщающаяЧПУсистемеPUMOTIXиспользуемыйдиаметртрубы.109 +The (% style="color:#8d69b2" %)**M94 P400 **(%%)command will be added to the generated NC by the postprocessor, informing the PUMOTIX CNC system of the used pipe diameter. 111 111 112 -[[image: rollgang_3.png||data-xwiki-image-style-alignment="center" height="250" width="373"]]111 +[[image:Pipe Diameter in G-code.png||data-xwiki-image-style-alignment="center" height="250" width="374"]] 113 113 114 -{{info title="** АвтоматическаяустановкадиаметраприоткрытииУПвPUMOTIX**"}}115 - ПриоткрытииданнойУПвPUMOTIXпараметрДиаметртрубыбудетвыставленавтоматически.Операторунеобходимоубедиться,чтоданноезначениесоответствуетфактическомудиаметруустановленнойтрубы.113 +{{info title="**Automatic diameter setting when opening the NC program in PUMOTIX**"}} 114 +When you open this program in PUMOTIX, the Pipe diameter parameter will be set automatically. The operator must ensure that this value corresponds to the actual diameter of the installed pipe. 116 116 {{/info}} 117 117 118 118 {{error}} 119 - ДляиспользованияприводногорольгангазначениепараметраДиаметртрубынедолжнобытьнулевым.Также,частотасигналовSTEP,рассчитаннаядлярольгангавзависимостиотдиаметратрубы,недолжнапревышатьмаксимальнуючастотусигналовSTEPиспользуемогоконтроллера.118 +To use a rollgang, the value of the Pipe Diameter parameter must not be zero. Also, the frequency of STEP signals calculated for the rollgang depending on the diameter of the pipe should not exceed the maximum frequency of STEP signals of the controller used. 120 120 {{/error}} 121 121 122 - ЕслипараметрДиаметртрубынеудовлетворяетуказаннымограничениям,использованиеповоротнойоси,длякоторойнастроенрольганг,будетнедоступнокакизУП,такиврежимеручныхперемещений,сотображениемсоответствующегопредупреждения.121 +If the Pipe Diameter parameter does not satisfy the specified restrictions, the use of the rotary axis for which the rollgang is configured will be unavailable both from the NC and in the manual movement mode, with the corresponding warning being displayed. 123 123 124 - Поздравляем,мынастроилидвигательдляуправленияприводнымрольгангом.Можноначинатьработу!123 +Congratulations, we have configured the motor to control the drive roller table. You can start working!