1 ===== bool Is_THC_Mode () =====
2
3 Checks if PUMOTIX is in plasma cutting mode.
4
5 Return value:
6
7 * true - if PUMOTIX is in plasma cutting mode;
8 * false - if another mode is active.
9
10 ===== number GetCurrentVoltage () =====
11
12 Getting the current voltage value in plasma cutting mode.
13
14 Return value:
15
16 * current voltage, V.
17
18 ===== number GetDesiredVoltage () =====
19
20 Obtaining the set value of the desired voltage in the plasma cutting mode.
21
22 Return value:
23
24 * desired voltage, V.
25
26 ===== void SetDesiredVoltage (number value) =====
27
28 Setting the desired voltage in plasma cutting mode.
29
30 Options:
31
32 * number value - the desired voltage, V.
33
34 ===== bool GetThcTorchOn () =====
35
36 Allows you to check if the torch is on in plasma mode.
37
38 Return value:
39
40 * true – if the torch is on in plasma mode.
41
42 ===== bool UseOmichSensor () =====
43
44 Allows you to check if the using ohmic sensor PLL-R2 is enabled in the Settings.
45
46 Return value:
47
48 * true – if the using ohmic sensor PLL-R2 is enabled.
49
50 ===== number GetOmichSensorDelta () =====
51
52 Getting the dZ value specified in the settings of the ohmic sensor.
53
54 Return value:
55
56 * dZ value specified in the settings of the ohmic sensor.
57
58 ===== void SetOmichSensorDelta (number value) =====
59
60 Setting the dZ value for ohmic sensor.
61