Changes for page Интерфейс модуля газокислородной резки
Last modified by writer on 2023/09/06 14:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -45,7 +45,8 @@ 45 45 “Diagnostics” Tab 46 46 47 47 (% class="relative-table wrapped" style="width:100.0%" %) 48 -|(% style="border-width:0.0px; width:110px" %)((( 48 +|(% style="border-width:0.0px" %)(% style="border-width: 0.0px;" %) 49 +((( 49 49 [[image:2019-09-06 12_19_55-PUMOTIX x64 Administrator.png||alt="Basic display panel module signals" data-xwiki-image-style-alignment="center" height="771" width="150"]] 50 50 51 51 (% class="imagetext" style="color: gray; text-align: center;" %) ... ... @@ -68,8 +68,6 @@ 68 68 69 69 * **'Stop' Signal** 70 70 Signal of hardware input “Stop”. It can be used, for example, to stop the execution of G-Code when the metal touches the nozzle or sensor ring of the capacitive torch height controller. When the input is triggered, there is no loss of coordinates, the G-Code can be continued from the stop. 71 -))) 72 - 73 73 * **Z Correction** 74 74 Displays the presence or absence of nozzle height correction above the metal. Gas cutting height control is carried out in three modes: 75 75 • external Z control; ... ... @@ -86,3 +86,4 @@ 86 86 Height correction indicator cutting up. In the autonomous axis mode or manual control, next to the indicator is a button for manual correction of the torch height up. 87 87 * **THC Down (DOWN)** 88 88 Height correction indicator cutting down. In the autonomous axis mode or manual control, next to the indicator is a button for manual correction of the torch height down. 88 +)))