Description of the Input and Output Signals of the Plasma Cutting Module

Last modified by writer on 2022/08/26 14:34

Input signals used in the plasma cutting module:

  • Estop – emergency stop signal;
  • Estop2 – second emergency stop signal, completely similar to the first. Allows to simplify the wiring of the machine, if the alarm signals from the sensors have different levels of operation;
  • EstopMPG – emergency stop signal received from MPG pendant (hardware signal support required);
  • Probing – signal from a probing sensor (material surface sensor);
  • Probing2 – additional probing sensor signal;
  • Probing3 – additional probing sensor signal;
  • THCUp – up regulation signal transmitted by an external THC block performing up / down regulation;
  • THCDown – a down regulation signal transmitted by an external THC block that performs up / down regulation;
  • THCAok – ArcOK signal input;
  • Stop – signal "Stop" or "Collision", machine stop without loss of coordinates;
  • Door – an input signaling the open door of the protective cabin (It stops the execution of the G-Code when triggered. It differs from the Stop input in that when the Door signal is active, G-code can be executed manually through the MDI window and torch control);
  • Start – signal "Start" of the G-code;
  • TorchDetachment – signal "Torch Detachment";
  • UserInput_0 - UserInput_14 – user input signals for use in PUMOTIX macros.

Output signals used in the plasma cutting module:

  • THCTorch – output controlling the torch;
  • THCRegLocked – output for indicating lockout control. It can be used to control an external Z-axis controller;
  • EstopState – signals that the system is in the off state or in the emergency stop state;
  • IdleState – signals that the system is idle;
  • RunningState – signals that the system is busy and is moving along the path;
  • MillingModeActive – signals that the system is in the "Milling" mode;
  • PlasmaModeActive – signals that the system is in the "Plasma cutting" mode;
  • OxyModeActive – signals that the system is in the "Oxy-fuel cutting" mode;
  • ChangePump – presence of the Charge Pump signal;
  • Aspirator – fan output for aspiration table;
  • Aspirator2 – additional fan output for aspiration table;
  • OmichSensorEnable – output for switching on the ohmic sensor measuring circuit;
  • UserOutput_1 - UserOutput_14 – user output signals for use in PUMOTIX macros.