Changes for page Пробинг

Last modified by writer on 2023/09/08 18:38

From version 3.1
edited by writer
on 2023/08/09 19:07
Change comment: There is no comment for this version
To version 4.1
edited by writer
on 2023/09/08 18:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,4 +1,4 @@
1 -===== **number GetGeneralProbeFeed()** =====
1 +===== number GetGeneralProbeFeed() =====
2 2  
3 3  Getting the material search speed specified in the parameters of the milling mode.
4 4  
... ... @@ -6,7 +6,7 @@
6 6  
7 7  * material search speed, mm/min.
8 8  
9 -===== **number GetGeneralTipHeight()** =====
9 +===== number GetGeneralTipHeight() =====
10 10  
11 11  Obtaining a correction for the height of the probing sensor specified in the parameters of the milling mode.
12 12  
... ... @@ -14,7 +14,7 @@
14 14  
15 15  * correction for the height of the probe probe, mm (default value: 0).
16 16  
17 -===== **number GetGeneralTipDiam()** =====
17 +===== number GetGeneralTipDiam() =====
18 18  
19 19  Obtaining a diameter of the stylus tip during horizontal probing specified in the parameters of the milling mode.
20 20  
... ... @@ -22,7 +22,7 @@
22 22  
23 23  * stylus tip diameter, mm (default value: 0).
24 24  
25 -===== **bool UseProbingPosition()** =====
25 +===== bool UseProbingPosition() =====
26 26  
27 27  Allows you to check if the XY probe position is enabled in the settings.
28 28  
... ... @@ -30,7 +30,7 @@
30 30  
31 31  * true – if probe position coords specified.
32 32  
33 -===== **number GetProbingPosition(number axisId)** =====
33 +===== number GetProbingPosition(number axisId) =====
34 34  
35 35  Getting the machine coordinate of the probing sensor along the specified axis.
36 36  
... ... @@ -42,7 +42,7 @@
42 42  
43 43  * the machine coord of probing sensor along the specified axis.
44 44  
45 -===== **number GetSensorType()** =====
45 +===== number GetSensorType() =====
46 46  
47 47  Getting the type of probing sensor specified in the probing settings.
48 48