1 | ===== number, bool ReadModbusRegister(string name) ===== | ||
2 | |||
3 | Getting Modbus-register value. | ||
4 | |||
5 | Options: | ||
6 | |||
7 | * string name – the register name configured in the Modbus setup menu. | ||
8 | |||
9 | Return values: | ||
10 | |||
11 | * value – Modbus-register value. Returns the last successfully read value from the cache, refreshed at 100ms intervals (the frequency of updates may vary depending on certain conditions). Returns 0 if the value has never been successfully read; | ||
12 | * is_online – boolean value that determines whether the last attempt to read the value of the Modbus register was successful. | ||
13 | |||
14 | ===== number, bool ReadModbusRegisterUpdated(string name) ===== | ||
15 | |||
16 | Getting Modbus-register value without cash. The register value is requested every time the command is invoked. | ||
17 | |||
18 | Options: | ||
19 | |||
20 | * string name – the register name configured in the Modbus setup menu. | ||
21 | |||
22 | Return values: | ||
23 | |||
24 | * value – Modbus-register value; | ||
25 | * is_online – boolean value that determines whether the last attempt to read the value of the Modbus register was successful. | ||
26 | |||
27 | ===== bool WriteModbusRegister(string name, number value) ===== | ||
28 | |||
29 | Setting Modbus-register value. | ||
30 | |||
31 | Options: | ||
32 | |||
33 | * string name – register name configured in the Modbus setup menu; | ||
34 | * number value – the register value to be set (16-bit integer). | ||
35 | |||
36 | Return value: | ||
37 | |||
38 | * true – if the setting of the Modbus register value is successful. | ||
39 | |||
40 | ===== number1, ... , numberN, bool ReadModbusMultipleRegistersUpdated(string name, number count) ===== | ||
41 | |||
42 | Getting values of several Modbus registers in a row without using a cache. | ||
43 | |||
44 | Options: | ||
45 | |||
46 | * string name – register name configures in the Modbus setup menu; | ||
47 | * number count – number of requested registers. | ||
48 | |||
49 | Return values: | ||
50 | |||
51 | * value1, ... , valueN – Modbus-register values; | ||
52 | * is_online – boolean value that determines whether the last attempt to read the value of the Modbus register was successful. | ||
53 | |||
54 | ===== bool WriteModbusMultipleRegisters(string name, number count, number value1, ... , number valueN) ===== | ||
55 | |||
56 | Setting of several Modbus registers in a row. | ||
57 | |||
58 | Options: | ||
59 | |||
60 | * string name – register name configured in the Modbus setup menu; | ||
61 | * number count – number of registers to write; | ||
62 | * number value1, ... , number valueN – the register value to be set (16-bit integer). | ||