PLCM-R1 Setup

Last modified by writer on 2024/05/14 13:56

  1. Using power injector connect the pendant according to the diagram below.
    The axis selection LEDs should light up if connected correctly. This indicates that the remote control is turned on, but is not yet in contact with the control program.

    PLCM-R1_en.png

  2. Run PUMOTIX.
    Open Plugins Configuration window via menu "Plugins" → “Plugins Configuration” and set the "Active" sign for plugin "CNC pendants".

    Pednant plugin On.png

    After that open the CNC pendants window for PLCM-R1 setup via "Plugins" menu.

    CNC pendant menu.png

  3. Setup the PLCM-R1 with PUMOTUX using the plugin.
    Select the pendant on the "Selected device" field. The list of devices is loaded automatically depending on the pendants connected to the PC.
    You must make a selection in the “Selected profile” field to configure the pendant. The list of profiles is loaded automatically depending on the selected module. PUMOTIX comes with default PLCM-R1 configurations but you can also create a custom configuration.

    Empty Pendant plugin Window.png

    Next you will see on your screen the model of pendant and fields with commands for pendant buttons. Setup the pendant and press the "Apply" button.
    PLCM-R1_setup_window.png

  4. Establish a connection between the PC and the pendant.
    If you have configured the pendant but all the axis LEDs continue to light, you will need to change the PLCM-R1 network settings. Use the settings button in the upper right corner of the window to do this.
    PLCM-R1_setings_child_window.png

    Set the IP address the same subnet with your PC (example: PC IP address is 192.168.10.5, mask 255.255.255.0, set the pendant IP address 192.168.10.23, mask 255.255.255.0, or another free IP address). Press the "Apply".
    After setting applying pendant LED "Connect" will light up.

  5. Close the settings window - your pendant is ready to use.