Wiki source code of Управление шпинделем по Modbus на примере Sunfar E550 и платы расширения PLCM-B1-G2
Last modified by writer on 2022/10/17 17:57
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | You will need a frequency converter (hereinafter referred to as the FC) with support for Modbus RTU control, such as Sunfar E500, to control the spindle via Modbus via the PLCM-B1-G2 expansion board. | ||
2 | |||
3 | Modbus spindle control setting procedure: | ||
4 | |||
5 | 1. Set FC to the control mode using the Modbus RTU protocol (RS-485) and remember the COM port settings in FC (count of bits per second, data bits, parity and stop bits). | ||
6 | |||
7 | Example for Sunfar E500. | ||
8 | |||
9 | |=(% style="text-align: center; width: 150px;" %)Function code|=(% style="text-align: center; width: 100px;" %)Value|=(% style="text-align:center" %)Description | ||
10 | |(% style="width:150px" %)F0.00|(% style="width:100px" %)2|Frequency reference source - external data transfer | ||
11 | |(% style="width:150px" %)F0.02|(% style="width:100px" %)0002|Trigger channel selection - serial data port | ||
12 | |(% style="width:150px" %)F4.00|(% style="width:100px" %)0114|Data transfer settings - speed selection: 9600 bps, parity check, Modbus data transfer protocol | ||
13 | |||
14 | (% style="margin-left: 30.0px;" %) | ||
15 | 2. Connect FC to the PLCM-B1-G2 expansion board via RS-485 interface. | ||
16 | |||
17 | (% style="margin-left: 30.0px;" %) | ||
18 | 3. Purchase the "[[MODBUS protocol support>>http://pumotix.ru/#soft]]" option or activate a trial period for this option in the menu "Configuration" → "License Manager" → "Common". | ||
19 | |||
20 | (% style="margin-left: 30.0px;" %) | ||
21 | 4. Enable and configure Modbus in the menu "Configuration" → "Modbus Setup". | ||
22 | |||
23 | Create new Modbus-master. Number of COM port is PLCM. The rest of the settings should be exactly the same as in the FC (in the screenshot, an example of a standard configuration of the COM port of Sunfar E500). | ||
24 | |||
25 | [[image:modbus_master_en.png||alt="master_plcm.png" data-xwiki-image-style-alignment="center" height="300" width="367"]] | ||
26 | |||
27 | You need to add registers to control the FC and read statuses from FC. For example you need to configure registers named **SpindleMode**, **SpindleRPM** and **SpindleStatus**. | ||
28 | |||
29 | We recommend using exactly these names, since in the future, registers will be accessed from background operations by their names. | ||
30 | |||
31 | (% style="text-align:center" %) | ||
32 | [[image:Modbus_Settings_example_E500.png||alt="registers_plcm.png" data-xwiki-image-style-alignment="center" height="444" width="1000"]] | ||
33 | |||
34 | {{success}} | ||
35 | Register numbers must be specified as decimal values. | ||
36 | {{/success}} | ||
37 | |||
38 | {{warning}} | ||
39 | These values can be indicated in HEX (hexadecimal) in the instructions for the frequency converter. For example, 0x1001, 0x1002 | ||
40 | {{/warning}} | ||
41 | |||
42 | (% style="margin-left: 30.0px;" %) | ||
43 | 5. Create new background operation (macro) through [[the macro manager>>doc:Руководство пользователя.Описание M-кодов.Управление макросами и фоновыми операциями.WebHome]]. | ||
44 | |||
45 | The main task of the background macro is to monitor the current state and spindle speed and send the values to the frequency converter via Modbus. | ||
46 | |||
47 | An example of [[background operation>>doc:Руководство пользователя.Описание фоновых операций.Создание фоновой операции.WebHome]] **modbus_spindle.bm** for ModBus spindle control posted in attachment. This file must be added to background operations list. | ||
48 | |||
49 | **[[Download background operation>>attach:modbus_spindle (1).bm]]** | ||
50 | |||
51 | {{warning}} | ||
52 | Access to Modbus registers from macros is done by the name of the Modbus register case sensitive! For example, **SpindleRPM** and **SpindleRpm** are different registers. | ||
53 | {{/warning}} | ||
54 | |||
55 | (% style="margin-left: 30.0px;" %) | ||
56 | 6. Enable the background operation. Make sure that the operation has started and is working properly. This will be indicated by the green indicator to the right of the operation name. | ||
57 | |||
58 | (% style="text-align:center" %) | ||
59 | [[image:Macros_Manager_wndw.png||alt="2021-11-29 14_18_03-Управление макросами.png" data-xwiki-image-style-alignment="center" height="400" width="544"]] | ||
60 | |||
61 | The spindle should now turn on and off if everything is configured correctly. The spindle speed accordingly must also change at the FC when it changing in PUMOTIX. |